| Inspection |
| 1. |
Measure the pressure of high pressure line by measuring voltage output between terminals No. 1 and No. 2.
|
| 2. |
Inspect the voltage value whether it is within the specified range.
|
| 3. |
If the measured voltage value is not within the specification, replace the A/C pressure transducer. |
| Replacement |
| 1. |
Disconnect the negative (-) battery terminal. |
| 2. |
Recover the refrigerant with a recovery/charging station.
|
| 3. |
Disconnect the A/C pressure transducer connector (A). |
| 4. |
Remove the A/C pressure transducer (B).
[Without Heat Pump]
[With Heat Pump]
|
| 5. |
Install in the reverse order of removal.
|
A/C Pressure Transducer Description and Operation
Evaporator Temperature Sensor Description and Operation