Kia Soul EV: High Voltage Charging System / Normal Charge Cable Lock Actuator Repair procedures

Kia Soul EV (PS EV) 2015-2020 Service Manual / EV Battery System / High Voltage Charging System / Normal Charge Cable Lock Actuator Repair procedures

Removal and Installation
1.
Shut off the high voltage.
(Refer to Battery Control System – “High Voltage Shut-off Procedure”)
2.
Disconnect the auxiliary battery (12V) negative (-) terminal.
3.
Disconnect the connector (A).
4.
Remove the actuator by loosening the bolts (B).

Tightening torque : 0.98-3.92 N.m (0.1-0.4 kgf.m, 0.72-2.9 lb-ft)

5.
Install in the reverse order of removal.
Normal Charge Cable Lock Actuator Description and Operation
Description and Operation It prevents the normal charge cable theft by operating the actuator when the door is locked.The normal charge cable can be connected only when the door is unlocked. An ...

High Voltage Distributing System
...

Other information:

Kia Soul EV (PS EV) 2015-2020 Service Manual: General Safety Information and Caution


Safety Precaution     Since electric vehicles contain high voltage batteries, mishandling the high voltage system or vehicle may lead to a serious accident, including electric shock and electric leakage.     • Be sure to shut o ...

Kia Soul EV (PS EV) 2015-2020 Service Manual: Components and Components Location


Component Location 1. Head cap2. Rear wiper arm nut3. Rear wiper arm & blade4. Grommet5. Rear wiper motor assembly6. Rear wiper motor bolt ...

Copyright © www.ksoulev.com 2020-2024