Kia Soul EV: High Voltage Charging System / Normal Charge Cable Lock Actuator Repair procedures

Kia Soul EV (PS EV) 2015-2020 Service Manual / EV Battery System / High Voltage Charging System / Normal Charge Cable Lock Actuator Repair procedures

Removal and Installation
1.
Shut off the high voltage.
(Refer to Battery Control System – “High Voltage Shut-off Procedure”)
2.
Disconnect the auxiliary battery (12V) negative (-) terminal.
3.
Disconnect the connector (A).
4.
Remove the actuator by loosening the bolts (B).

Tightening torque : 0.98-3.92 N.m (0.1-0.4 kgf.m, 0.72-2.9 lb-ft)

5.
Install in the reverse order of removal.
Normal Charge Cable Lock Actuator Description and Operation
Description and Operation It prevents the normal charge cable theft by operating the actuator when the door is locked.The normal charge cable can be connected only when the door is unlocked. An ...

High Voltage Distributing System
...

Other information:

Kia Soul EV (PS EV) 2015-2020 Service Manual: Cowl Cross Bar Assembly Components and Components Location


Component Location 1. Cowl cross bar assembly ...

Kia Soul EV (PS EV) 2015-2020 Service Manual: General Safety Information and Caution


Precautions General Precautions Please read the following precautions carefully before performing the airbag system service. Carefully observe the instructions described in this manual as misuse of airbags may result in accidental deployment of airbags, damage or injuries. • Exc ...

Copyright © www.ksoulev.com 2020-2024