Kia Soul EV: High Voltage Charging System / Normal Charge Cable Lock Actuator Repair procedures

Kia Soul EV (PS EV) 2015-2020 Service Manual / EV Battery System / High Voltage Charging System / Normal Charge Cable Lock Actuator Repair procedures

Removal and Installation
1.
Shut off the high voltage.
(Refer to Battery Control System – “High Voltage Shut-off Procedure”)
2.
Disconnect the auxiliary battery (12V) negative (-) terminal.
3.
Disconnect the connector (A).
4.
Remove the actuator by loosening the bolts (B).

Tightening torque : 0.98-3.92 N.m (0.1-0.4 kgf.m, 0.72-2.9 lb-ft)

5.
Install in the reverse order of removal.
Normal Charge Cable Lock Actuator Description and Operation
Description and Operation It prevents the normal charge cable theft by operating the actuator when the door is locked.The normal charge cable can be connected only when the door is unlocked. An ...

High Voltage Distributing System
...

Other information:

Kia Soul EV (PS EV) 2015-2020 Service Manual: Components and Components Location


Component Location 1. Cluster assembly2. Seat belt switch3. Brake fluid level warning switch4. Parking brake switch5. Door switch6. Tailgate switch7. Wheel speed sensor8. ABS ECU ...

Kia Soul EV (PS EV) 2015-2020 Service Manual: Components and Components Location


Components Location 1. Torsion beam axle2. Shock absorber3. Coil spring assembly ...

Copyright © www.ksoulev.com 2020-2023