Kia Soul EV: High Voltage Battery Control System / Main Fuse Specifications
Item
| Specification
|
Rated Voltage (V)
| 450 (DC)
|
Rated Current (A)
| 250 (DC)
|
Item
| Specification
| Remark
|
Safety Plug Cable Resistance (?)
| Less than 1 (20°C)
| Checkable by multi tester
|
Main Fuse Resistance (?)
| Less than 1 (20°C)
| Checkable by multi tester
|
Inspection
•
Be sure to read and follow the “General Safety Information
and Caution” before doing any work related with the high voltage
system. Failur ...
Description
Installed in the safety plug, the main fuse protects the high voltage circuit from overcurrent. ...
Other information:
Component Location
1. Floor console assembly
...
Troubleshooting
Fault codeFail descriptionRemedy61Compressor CAN signal faultCompressor operation state error receive1. Check HV, LV connector connection. 2. Check LV connector pin condition. 3. Check vehicle inverter fuse condition. 4. A/C ON then check compressor operatio ...