Kia Soul EV: High Voltage Battery Control System / Components and Components Location

Kia Soul EV (PS EV) 2015-2020 Service Manual / EV Battery System / High Voltage Battery Control System / Components and Components Location

Components Location
High Voltage Battery System Assembly

1. BMS ECU
2. Main Relay
3. Pre Charge Relay
4. Pre Charge Resistor
5. Battery Current Sensor
6. Safety Plug
7. Main Fuse
8. Battery Temperature Sensor
9. Runaway Arresting Device (RAD)
10. High Voltage Battery Heater (With heater system)
11. High Voltage Battery Heater Relay (With heater system)
12. High Voltage Battery Heater Fuse (With heater system)
13. High Voltage Battery Heater Temperature Sensor (With heater system)

1. BMS ECU
2. Main Relay
3. Pre Charge Relay

4. Pre Charge Resistor
5. Battery Current Sensor
6. Safety Plug

7. Main Fuse
8. Battery Temperature Sensor

9. Runaway Arresting Device (RAD)
10. High Voltage Battery Heater Temperature Sensor

11. High Voltage Battery Heater Fuse


Power Relay Assembly (Without heater system)

1. Main Relay (+)
2. Main Relay (-)
3. Pre Charge Relay
4. Pre Charge Resistor
5. Battery Current Sensor


Power Relay Assembly (With heater system)

1. Main Relay (+)
2. Main Relay (-)
3. Pre Charge Relay
4. Pre Charge Resistor
5. Battery Current Sensor
6. High Voltage Battery Heater Relay
7. High Voltage Battery Heater Fuse

High Voltage Battery Control System
...

Description and Operation
Description High Voltage Battery Control System High voltage battery control system consists of BMS ECU, PRA and it controls SOC (State of charge), output, trouble shooting, battery cell ba ...

Other information:

Kia Soul EV (PS EV) 2015-2020 Service Manual: Troubleshooting


Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to lack of refrigerant, air flow or compressor. Use the following table to find the cause of the problem. The numbers indicate the order of the lik ...

Kia Soul EV (PS EV) 2015-2020 Service Manual: Specifications


Specifications AVN Head Unit ItemSpecificationPower supplyDC 14.4V Negative groundDark current(Head unit only)USAACC OFF & ADM OFF and then after 96 hours : Max. 0.5mAACC OFF & ADM OFF and then before 96 hours (average) : Max. 10mAAfter ACC OFF & ADM OFF, Within 20 seconds (average ...

Copyright © www.ksoulev.com 2020-2021