Kia Soul EV: Driveshaft and axle / Specifications
Motor
| Joint type
| Max. permissible angle
|
Outer
| Inner
| Outer
| Inner
|
80KW
| BJ#92
| TJ#92
| 45°
| 21°
|
Tightening Torques
Item
| N.m
| kgf.m
| Ib.ft
|
Front
| Tire wheel hub nuts
| 88.3 ~ 107.9
| 9.0 ~ 11.0
| 65.1 ~ 79.6
|
Drive shaft coking nut
| 274.6 ~ 294.2
| 28.0 ~ 30.0
| 202.5 ~ 217.0
|
Strut assembly to knuckle
| 137.3 ~ 156.9
| 14.0 ~ 16.0
| 101.3 ~ 115.7
|
Caliper guide rod bolt
| 21.6 ~ 31.4
| 2.2 ~ 3.2
| 15.9 ~ 23.1
|
Brake caliper mounting bolt
| 78.4 ~ 98.0
| 8.0 ~ 10.0
| 57.8 ~ 72.3
|
Wheel speed sensor mounting bolt
| 6.8 ~ 10.7
| 0.7 ~ 1.1
| 5.0 ~ 7.9
|
Brake disc mounting screw
| 4.9 ~ 5.8
| 0.5 ~ 0.6
| 3.6 ~ 4.3
|
Lower arm to knuckle
| 58.8 ~ 70.6
| 6.0 ~ 7.2
| 43.4 ~ 52.1
|
Tie rod end ball joint nut
| 23.5 ~ 33.3
| 2.4 ~ 3.4
| 17.4 ~ 24.5
|
Rear
| Tire wheel hub nuts
| 88.2 ~ 107.8
| 9.0 ~ 11.0
| 65.0 ~ 79.5
|
Rear caliper guide rod bolt
| 21.6 ~ 31.4
| 2.2 ~ 3.2
| 15.9 ~ 23.1
|
Rear caliper to torsion beam axle
| 63.7 ~ 73.5
| 6.5 ~ 7.5
| 47.0 ~ 54.2
|
Rear hub assembly to torsion beam axle
| 49.0 ~ 58.8
| 5.0 ~ 6.0
| 36.2 ~ 43.3
|
Disc fixing screw
| 4.9 ~ 5.9
| 0.5 ~ 0.6
| 3.6 ~ 4.3
|
Motor
| Joint
| Lubricants
| Quantity
|
80KW
| BJ
| GRB006
| 105g (+10g/0)
|
TJ
| SH06-VX21
| 140g (+10g/0)
|
High Voltage Shut-off Procedure
Be sure to read and follow the “General Safety Information
and Caution” before doing any work related with the high voltage
syst ...
Special Service Tools
Tool Name / NumberIllustrationDescriptionBand installer09495-3K000Used to install ear type boot bandPuller09495-33000Used to remove spider assemblyBall joint puller09568-340 ...
Other information:
Replacement
1.
Open the glove box (A).
2.
Remove the air filter panel (A).
3.
Remove the filter cover (A) by pressing the knob.
4.
Replace the air filter (A) with a new one according to the direction of air filter.
•
To remove the filter easily, ...
Inspection
Normal Charge Port Relay
Check for continuity between the terminals.
1.
There should be continuity between terminals No.20 and No.10
when power and ground are connected to terminals No.10 and No.9 in the
ICM-A.
Folding Motor Relay
Check for continuity between the terminals.
...