System Configuration
PAS consists of 8 sensors (4 front & 4 rear) which detect
the obstacles and transmit the result in 3 separate warning levels, the
first, second and third to IPM (BCM) v ...
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the mode control actuator connector.
3.
Verify that the mode control actuator operates to the defrost mode when 12V is connected to terminal 3 and ground to terminal 7.
Verify that the mode control actuator operates to the vent m ...
Description and Operation
It prevents the normal charge cable theft by operating the
actuator when the door is locked.The normal charge cable can be
connected only when the door is unlocked. And if the door is locked
after the cable is connected, the cable cannot be disconnected by
actuat ...