Kia Soul EV: Heat Pump / Accumulator Repair procedures

Kia Soul EV (PS EV) 2015-2020 Service Manual / Heating,Ventilation, Air Conditioning / Heat Pump / Accumulator Repair procedures

Replacement
1.
Recover the refrigerant with a recovery/ recycling/ charging station.
   
Do not use the same A/C recovery / charging station as conventional belt-driven compressors.
Since the electric compressor uses high-voltage, POE oil with high resistivity should be used.
If PAG oil mixes into the POE oil of the system, dielectric breakdown may occur due to decreased volumetric resistivity and the A/C compressor may not work.
2.
Disconnect the negative (-) battery terminal.
3.
Remove the refrigerant line after loosening the mounting nuts (A).

4.
Remove the accumulator (A) after loosening the mounting bolt.

5.
Install in the reverse order of removal.
   
Do not use the same A/C recovery / charging station as conventional belt-driven compressors.
Since the electric compressor uses high-voltage, POE oil with high resistivity should be used.
If PAG oil mixes into the POE oil of the system, dielectric breakdown may occur due to decreased volumetric resistivity and the A/C compressor may not work.
Accumulator Description and Operation
Description Separates refrigerant in gas/liquid state so that only the refrigerant in gas state can flow into the compressor. ...

Refrigerant Temperature Sensor Components and Components Location
Components Location 1. Refrigerant Temperature Sensor #1 2. Refrigerant Temperature Sensor #2 ...

Other information:

Kia Soul EV (PS EV) 2015-2020 Service Manual: Schematic Diagrams


Circuit Diagram (1) Circuit Diagram (2) Circuit Diagram (3) SRSCM Connector Terminal Harness Connector Pin No.Function (Connector A)Pin No.Function (Connector B)1--1--2--2--3--3--4- -4--5GA/C Control Module (SBR PASS)5BPassenger Side ImpactSensor (High)6--6YPassenger Side ImpactSensor ...

Kia Soul EV (PS EV) 2015-2020 Service Manual: Outer Condenser Description and Operation


Description Condenses high temp-high pressure refrigerant when in A/C Mode (same role as the condenser in a conventional system). Evaporates low temp-low pressure refrigerant when in Heating Mode (same role as the evaporator in a conventional system). It is designed as down-flow type to facilit ...

Copyright © www.ksoulev.com 2020-2021