Other information:
Description
Pre-Charge Resistor is installed in the Power Relay Assembly
(PRA) and it protects the high voltage circuit by limiting the charging
current when the inverter capacitor is being pre-charged.
[With High Voltage Battery Heater System]
1. Main Relay (+)2. Main Relay (-)3. Pre Cha ...
Inspection
1.
Check that the red light flickers when the door lock or unlock button is pressed on the transmitter.
2.
Remove the battery (A) and check voltage if the red light doesn''t flicker.
Standard voltage : 3V
3.
Insert the battery (A) into the tester (09954-2P100).
4.
Pus ...