Other information:
Description
Installed in the Power Relay Assembly (PRA), the Pre-charge
Relay connects high voltage circuit when pre-charging the inverter
capacitor.
When the IG is ON, the current coming through the pre-charge
relay and the resistor charges the capacitor in the inverter and when
the cap ...
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the intake actuator connector.
3.
Verify that the actuator operates to the recirculation position when 12V is connected to terminal 3 and ground to terminal 7.
Verify that the intake actuator operates to the recirculated air posi ...