Kia Soul EV: High Voltage Battery Control System / Main Relay Specifications
Item
| Specification
|
ON
| Rated Voltage (V)
| 450
|
Rated Ampere (A)
| 200
|
Voltage Drop (V)
| Less than 0.1 (200A)
|
Coil
| Operation Voltage (V)
| 12
|
Resistance (?)
| 21.6 ~ 26.4 (20°C)
|
Item
| Specification
| Note
|
Main Relay Fixing Status
| NO
| Checkable by GDS
|
Main Relay Switch (-) Resistance (?)
| ?
| Checkable by multi tester
|
Main Relay Operation Beep
| "Clicking"
| Checkable by GDS and SST
|
Coil Resistance (?)
| 21.6 ~ 26.4 (20°C)
| Checkable by multi tester
|
Inspection
C-CAN Terminating Resistance Inspection (Multi Purpose Check Connector)
1.
Turn the ignition OFF.
2.
Measure the resistance between pins No. 20 and No. 17 of multi purpose check ...
Description
Main Relay is installed in the Power Relay Assembly (PRA) and it controls the high voltage line.
It connects the power between the high voltage battery pack and the high voltage joint ...