Kia Soul EV: High Voltage Battery Control System / Main Relay Specifications

Kia Soul EV (PS EV) 2015-2020 Service Manual / EV Battery System / High Voltage Battery Control System / Main Relay Specifications

Specification
Item
Specification
ON
Rated Voltage (V)
450
Rated Ampere (A)
200
Voltage Drop (V)
Less than 0.1 (200A)
Coil
Operation Voltage (V)
12
Resistance (?)
21.6 ~ 26.4 (20°C)

Item
Specification
Note
Main Relay Fixing Status
NO
Checkable by GDS
Main Relay Switch (-) Resistance (?)
?
Checkable by multi tester
Main Relay Operation Beep
"Clicking"
Checkable by GDS and SST
Coil Resistance (?)
21.6 ~ 26.4 (20°C)
Checkable by multi tester

Battery Management System (BMS) ECU Repair procedures
Inspection C-CAN Terminating Resistance Inspection (Multi Purpose Check Connector) 1. Turn the ignition OFF. 2. Measure the resistance between pins No. 20 and No. 17 of multi purpose check ...

Main Relay Description and Operation
Description Main Relay is installed in the Power Relay Assembly (PRA) and it controls the high voltage line. It connects the power between the high voltage battery pack and the high voltage joint ...

Other information:

Kia Soul EV (PS EV) 2015-2020 Service Manual: License Plate Lamps Repair procedures


Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the license plate lamp assembly (A). 3. Replace the bulb (B) after removing the license plate lamp (A). Installation 1. Install the bulb. 2. Install the license plate lamp assembly. ...

Kia Soul EV (PS EV) 2015-2020 Service Manual: Smart Key Repair procedures


Inspection 1. Check that the red light flickers when the door lock or unlock button is pressed on the transmitter. 2. Remove the battery (A) and check voltage if the red light doesn''t flicker. Standard voltage : 3V 3. Insert the battery (A) into the tester (09954-2P100). 4. Pus ...