Kia Soul EV: High Voltage Battery Control System / Main Relay Specifications

Kia Soul EV (PS EV) 2015-2020 Service Manual / EV Battery System / High Voltage Battery Control System / Main Relay Specifications

Specification
Item
Specification
ON
Rated Voltage (V)
450
Rated Ampere (A)
200
Voltage Drop (V)
Less than 0.1 (200A)
Coil
Operation Voltage (V)
12
Resistance (?)
21.6 ~ 26.4 (20°C)

Item
Specification
Note
Main Relay Fixing Status
NO
Checkable by GDS
Main Relay Switch (-) Resistance (?)
?
Checkable by multi tester
Main Relay Operation Beep
"Clicking"
Checkable by GDS and SST
Coil Resistance (?)
21.6 ~ 26.4 (20°C)
Checkable by multi tester

Battery Management System (BMS) ECU Repair procedures
Inspection C-CAN Terminating Resistance Inspection (Multi Purpose Check Connector) 1. Turn the ignition OFF. 2. Measure the resistance between pins No. 20 and No. 17 of multi purpose check ...

Main Relay Description and Operation
Description Main Relay is installed in the Power Relay Assembly (PRA) and it controls the high voltage line. It connects the power between the high voltage battery pack and the high voltage joint ...

Other information:

Kia Soul EV (PS EV) 2015-2020 Service Manual: Troubleshooting


Troubleshooting Trouble SymptomProbable causeRemedyVehicle pulls to one sideScoring of driveshaft ball jointReplaceWear, rattle or scoring of wheel bearingReplaceDefective front suspension and steeringAdjustment or ReplaceVibrationWear, damage or bending of driveshaftReplaceDrive Shaft rattle a ...

Kia Soul EV (PS EV) 2015-2020 Service Manual: Inlet Temperature Sensor Description and Operation


Description Inlet temperature sensor is installed on the No.8 module of high voltage battery and it detects the inner air temperature of battery. The operation of cooling fan depends on the inlet temperature sensor value. Inlet Temperature Sensor Installation (on the No.8 battery modu ...

Copyright © www.ksoulev.com 2020-2024